Setting The Pump Speed; Field Settings - Daikin EKHBH030BA Manual De Instalación

Unidad interior para bomba de calor de aire-agua
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Setting the pump speed

The pump speed can be selected on the pump (see "Main
components" on page 10).
The default setting is high speed (III). If the water flow in the system
is too high (e.g., noise of running water in the installation) the speed
can be set to medium speed (II) or low speed (I).
The available external static pressure (ESP, expressed in psi (kPa)) in
function of the water flow (gallons/min (l/min)) is shown in the graph
below.
9
8
7
6
5
II
4
3
I
2
1
0
3
4
5
60
55
50
45
40
35
30
II
25
20
15
I
10
5
0
12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42
EKHBH/X030BA
Indoor unit for air to water heat pump system
4PW62568-1 – 07.2010
III
6
7
8
9
10
[gallons/min]
III
[l/min]

Field settings

The indoor unit shall be configured by the installer to match the
installation environment (outdoor climate, installed options, etc.) and
user demand. Thereto, a number of so called field settings are
available. These field settings are accessible and programmable
through the user interface on the indoor unit.
Each field setting is assigned a 3-digit number or code, for example
[1-03], which is indicated on the user interface display. The first digit
[1] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.
A list of all field settings and default values is given under "Field
settings table" on page 35. In this same list, we provided for 2
columns to register the date and value of altered field settings at
variance with the default value.
A detailed description of each field setting is given under "Detailed
description" on page 26.
Procedure
To change one or more field settings, proceed as follows.
Temperature values displayed on the digital controller
(user interface) are default in °C.
To change the display to °F, push ib and jb
buttons simultaneously for 5 seconds. Execute same
procedure to change back to the °C display.
3
2
1
Press the z button for a minimum of 5 seconds to enter FIELD
SET MODE.
The $ icon (3) will be displayed. The current selected field
setting code is indicated ; (2), with the set value displayed to
the right
(1).
Press the bgi button to select the appropriate field
2
setting first code.
Press the bgj button to select the appropriate field
3
setting second code.
Press the pfi button and pfj button to change
4
the set value of the select field setting.
Save the new value by pressing the pr button.
5
6
Repeat step 2 through 4 to change other field settings as
required.
When finished, press the z button to exit FIELD SET MODE.
7
NOTE
Changes made to a specific field setting are only
stored when the pr button is pressed. Navigating to a
new field setting code or pressing the z button will
discard the change made.
1
Installation manual
25

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ekhbx030baEkhbh054baEkhbx054ba

Tabla de contenido