CST/BERGER 56-DGT2 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
D) Using the adjusting pin
provided in the case, turn the
reticle adjusting screws until
half the displacement has
been removed. Loosen one
screw 1/4 turn, then tighten
the opposing screw 1/4 turn.
E) Repeat steps A through D
until there is no displacement
of the target when the
instrument is turned about its
vertical axis.
Setting The Vertical Zero Position
PROCEDURE
Accurately level the instrument
Press and hold the V% key while pressing
the power key. The instrument display will
enter the vertical zero adjustment mode.
Turn the telescope past the zero point.
The display will show "STEP 1".
Sight the telescope at a target that is level
with the instrument within 10 seconds.
Press "V%". This will store the data for the
first point. The display will show "STEP 2".
Reverse the telescope and re-sight the
original target. Press the "V%" key. This will
store the data for the second point and
establish a vertical zero point at level. Once a
key is pressed, the instrument will beep and
return to regular measurement mode.
16 • DGT2 - DGT10
KEY
DISPLAY
N/A
V%
V
2X
V
H
R
V
V%
H
R
V%
V 2 6 1 1 2 4 3
H
1 8 0 0 0 0 0
R
L
O S E
9 5 1 0 2 0
L
S E - - 1
9 5 1 0 2 0
L
S E - - 2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

56-dgt10

Tabla de contenido