22. Locate power supply (BB) and plug cord into back of light
switch. Insert power supply plug into 120V receptacle.
MAINTENANCE AND CLEANING
WARNING: Disconnect power and air before the mainte-
nance is performed. Never perform any maintenance with the
cabinet under pressure.
Cleaning: Please clean the blast cabinet or parts with a soft
cloth. DO NOT use any solvents to clean the blast cabinet or
parts inside of the cabinet. If the viewing window becomes
such that the work area cannot be viewed, peel off the win-
dow protector film included with this unit and replace with new
window protector film.
Air Supply Maintenance: Every day maintain the air supply
according to the manufacturer's instructions. Drain the mois-
ture from the filter and compressor regularly.
Performing routine air supply maintenance will reduce mois-
ture contamination of abrasive media which will increase
performance.
Before operation check fittings and hoses making sure all
connections are leak free.
WARNING: Inspect gloves and make sure there are no
punctures. If you feel air blowing in the glove, replace them
immediately. DO NOT use a damaged or punctured glove.
Adding abrasive: Do not overfill. See specifications for
maximum abrasive amount.
14