5. Start-up
5.1 Initial start-up
6. Allocating locking authorisations
The product is supplied in so-called simple operation mode for stand-alone
operation (SA). These instructions only describe how to start up in this operation
mode.
• Details of use of the product with software applications can be found in the
relevant software documentation.
• The "Stand-Alone" operation mode will be permanently shut off once the product
is configured for the first time using the Dialock MDU. After that, reactivating this
operation mode is only possible after a reset. For detailed information on reset,
please contact Häfele.
The work operations only need to be carried out once during initial start-up.
NOTE
Malfunction due to outdated Dialock firmware
To ensure that the current Dialock firmware is running on the terminal, the
device has to be flashed (programmed) using the mobile programming unit
(MDU) during start-up. In case of questions concerning the firmware version
or the procedure please contact Häfele.
The individual work operations must be carried out within a short time window.
Therefore:
• First study every work operation and have the keys that are needed at the ready
before commencing with initial start-up.
• Perform the work operations quickly and without interruptions.
For safety reasons, the initial start-up can only take place within 5 seconds after the
batteries were inserted.
If this time window is missed, the initial start-up can be started again by removing
the batteries and inserting them again.
For step-by-step instructions "Start-up" see illustrations
starting on page 62.
NOTE
Warning of abuse!
Unauthorised persons can gain access to rooms using the programming and
clearing keys.
> Only personnel who are authorised by the operator may allocate locking
authorisations!
> Take care when allocating locking authorisations to avoid overlapping
or mistakes.
> Keep programming and clearing keys in a safe place and protect from
abuse.
en