3. CONTROL AND ADJUSTMENT
When the charger is installed correctly, the charger should be set up to suit the battery connected.
To set up the charger, apply mains power and enter the setup menu by pressing "SETUP" for three seconds.
The charger will enter a standby mode (no power applied to the battery terminals) and the user can set up the unit accordingly.
See the next table for all possible adjustments.
3.1. Monitor menu
The monitor menu is visible when power is applied to the charger.
Setup (3 seconds)
-
+
-
+
The following table shows the consecutive lines when scrolling through the menu with the up/down keys:
Displayed info
Battery voltage / current
Battery voltage
Battery charge current
Battery temperature
*1
Mains current
Battery voltage out 1
*2
Battery charge current out 1
Battery voltage out 2
*2
Battery charge current out 2
Battery voltage out 3
*2
Battery charge current out 3
Warning message
*3 *4
Error message
*3 *4
BMS operation
*3
*1
A valid temperature is shown. " --- " means no sensor information or "Err" means invalid sensor data.
The output channel number is shown in the first segment; only visible in a three output model.
*2
*3
These items are only visible when relevant.
*4
After a short delay a scrolling text is shown with the error description.
With the up/down keys the user can scroll through the monitor menu.
Holding either up or down for three seconds will start the auto scrolling mode: all Monitor menu items will be shown for 5 seconds.
The auto scroll mode can be exit by pressing up or down once.
8
select
setup
select
Blinking: Use the up/down keys to
adjust.
Icons
Segments
.
.
.
.,,
.
.
*2
.
.
*2
.
.
*2
.
select
setup
select
setup
Units
A
V
A
°C/°F
A
V
A
V
A
V
A
Confirm by pressing select and exit
with setup.