Hydraulic schematic
T
2
1
P
9
Item
Description
1
Hydraulic fluid inlet port SAE 4 ORB
2
Hydraulic fluid return to tank SAE 6 ORB
3
Hydraulic motor
4
Lube outlets 0.25 in NPTF
5
Flow control valve
6
Hydraulic fluid to vent valve
7
Orifice 0.013 in (0.33 mm) diameter
8
Pressure control valve
9
Solenoid valve
Grease output vs. hydraulic input
Grease output, in
3
/min (cm
3
/min)
40
(655)
35
(573)
30
(491)
25
(409)
20
(327)
15
(245)
10
(163)
5
(81)
0
1.0
1.5
(3,7)
(5,6)
8
6
7
2.0
2.5 3.0
(7,5)
(9,4)
Fig. 1
3
4
5
3.5
4.0
(11,3)
(15,1)
(13,2)
7
80 °F
(27 °C)
20 °F
(–2 °C)
0 °F
(–18 °C)
–20 °F
(–29 °C)
4.5
5
(17,0)
(18,9)
Hydraulic input, gpm (liter/min)