Pump dimensions
. in
( mm)
. in
( mm)
Installation
The pump is tested in lightweight oil which is
left in to protect the pump from corrosion.
Flush the pump before connecting it to the
system to prevent contamination of the
grease with residual oil.
The pump has flow and fixed
400 psi (27.5 bar) pressure controls
integrated into the manifold (65).
A normally closed on/off solenoid
valve (66 and 67) is also integrated into the
manifold and will start or stop the pump
operation.
NOTE
If it is necessary to drill mounting holes
into reservoir cover, refer to Fig. 3 for
hole pattern and dimensions.
. in
( mm)
. in
( mm)
. in
( mm)
1 Mount pump securely on the drum cover
so that it cannot move or vibrate during
operation. Refer to Fig. 4, page 9.
2 Attach hydraulic supply line to the inlet
and return line to the tank ports.
3 Connect material supply line to the pump
outlet.
4 Plug the unused outlet on the opposite
side of the pump.
5 Install high pressure shut-off valve in the
material supply line. (if required).
6 Connect 24 V
solenoid coil (67), using the
supplied plug.
Operation
1 Shut off the material supply line valve.
2 Turn on the hydraulic pressure.
3 Energize the solenoid on/off valve.
4 Prime the pump by slowly opening the
shut-off lubricant supply line valve.
5 Make sure all air has been expelled from
the pump and even lubricant flow is
achieved.
6 Adjust the flow to desired application
requirements.
. in
( mm)
. in
( mm)
. in
( mm)
Ø. in
( mm)
power supply to the
8
. in
( mm)
( x ) Ø. in
( mm)
( x)
/
-
WARNING
Do not exceed
400 psi (27.5 bar) working
hydraulic pressure. Use
high pressure components
to reduce risk of serious injury including
fluid injection and splashing in the eyes
or on the skin.
All accessories connected to the pump
outlet must have at least
3 500 psi (241 bar) minimum hydraulic
operating pressure. All accessories
connected to the pump inlet must have
at least 3 000 psi (206 bar) minimum
working pressure.
Failure to comply may result in
serious personal injury.
Fig. 3