Operational Features; Safety Tips - Toyotomi TAD-T38J Manual De Instrucciones

Acondicionador de aire portatil
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SUMMARY
The idea behind the unit is to provide a localized supply of cool air.
The unit will greatly enhance your personal comfort whether at a
work station or even in your favorite chair.
Four (4) casters enable you to move the unit easily from room to
room. It cools and dries the air at the same time so that you can
stay comfortable even when it's humid or rainy outside. Also your
furnishings and fabrics are kept in good condition when it's used
as a dehumidifier.
Conventional air conditioners use large quantities of energy to cool
an entire room, including walls and furniture. The unit creates a
zone of cool and dry air only where it is needed. It does not waste
energy cooling the surroundings.
It's easy to operate. Once you set the desired function, all functions
will be memorized in the unit. The built-in timer allows from 1 to
12 hours of operation, which will automatically turn the unit on
and off. This is especially convenient at bedtime.
Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by us-
ing the venting kit accessory, which is induded wiyh the unit.

OPERATIONAL FEATURES

1. COOLING OPERATION
Normally, cool air is directed out the air outlet grill by the
circulation fan which has three (3) stages of fan speed.
2. AUTOMATIC OPERATION
The unit will select its mode and fan speed automatically
base on the environment temperature.
3. THERMO CONTROL
The compressor will automatically shift to ON or OFF to
maintain the desired temperature.
4. TIMER OPERATION
The unit will turn on and off after the designated period of
time (1, 2, 3, ...12 hours).
5. AUTOMATIC SHUT-OFF MECHANISM WHEN THE DRAIN
TANK IS FULL
When the drain tank is full, the unit will be automatically
shut off. It is always required to press the power button
twice to resume operation after the condensed water is re-
moved from the tank.
6. TRIPLE AIR FILTERS
A pre-filter protects the unit from dust, HAF filter (option)
cleans circulation air and a charcoal filter eliminates un-
pleasant odor.
1. DESCRIPTION
Fig. A
FRONT
A1
Remote control (Removable)
A2
Air outlet grille
A3
Horizontal louver
A4
Vertical louver
A5
Emergency ON/OFF switch
A6
Front panel
Fig. B
REAR
B1
Air intake grille
B2
HAF filter (option)
B3
Charcoal filter (inside)
B4
Filter clamp (inside)
B5
Air intake opening
B6
Drain water outlet
B7
Power supply cord
B8
Cable hook
B9
Exhaust outlet
B10
Caster
B11
LCDI Power plug
Fig. C
REMOTE CONTROL (REMOVABLE)
C1
Power button
C2
Fan speed button
C3
Mode button
C4
Down button
C5
LCD display
C6
Clock button
C7
Timer button
C8
C/F toggle button
C9
UP button
C10
Fan speed indicator
C11
Mode indicator
C12
Launch signal indicator
C13
Clock indicator
C14
C/F indicator
C15
Set temp indicator
C16
Timer setting indicator
C17
Timer ON/OFF indicator
Fig. I
EXHAUST DUCT SET
I1
Exhaust duct hose adapter nozzle (4 pcs.)
I2
Exhaust duct hose (2 pcs.)
Fig. J
WINDOW PANEL KIT
J1
Window panel "C"
J2
Window panel extension (2 pcs.)
J3
Exhaust duct hose grille (2 pcs.)
J4
Cover (2 pcs.)
J5
Screws

2. SAFETY TIPS

IMPORTANT
¡ Read instructions carefully before operation.
¡ The unit should be operated when the room temperature is
between 64˚F (18˚C) to 95˚F (35˚C). If the room temperature
is below 64˚F (18˚C), ice may form on the coils. If the room
temperature is above 95˚F (35˚C), the compressor will auto-
matically shut off to protect itself.
¡ Always wait 3 minutes to restart after turning unit off.
WARNING
¡ NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.
¡ Keep children away from unit. Children are particularly li-
able to this danger. The inside fan is running at high speed.
Covering it may deteriorate air conditioner performance or
cause it to become inoperative.
¡ NEVER insert objects of any kind into the air intake or air outlet.
¡ DO NOT unplug if your hands are wet. An electrical shock
may occur.
¡ DO NOT operate in a wet location.
¡ ALWAYS plug into 115V, 60Hz, single phase electrical outlet.
¡ Be sure plug fits the receptacle securely.
¡ DO NOT run power cord under carpets, rugs, or floor mats
of any kind.
¡ DO NOT attempt to shorten or alter power cord in any way.
¡ DO NOT apply any excessive force or pressure to the power
supply cord.
¡ Make sure that the plug is free of dust.
¡ DO NOT use an extension cord.
¡ DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.
¡ If there is a fear of lightning, stop the unit and disconnect
the power supply cord.
¡ DO NOT touch the evaporator, condenser and pipes.
¡ DO NOT operate with filter removed.
¡ ALWAYS lift the unit with two people.
CAUTION
¡ Keep unit more than 20 in. (50 cm) away from any objects or
wall. (Fig. D)
¡ If the unit is operated in COOL mode in an area of very high
moisture, the top plate and the rear plate may get covered
with a mist. Wipe off any mist before it has a chance to get
on the floor or rug.
¡ Remove drain water before moving unit.
¡ To minimize corrosion, DO NOT use in damp, salty air area.
¡ DO NOT operate in direct sunlight.
¡ DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and
medicine.
¡ DO NOT place any animals, plants or combustion equip-
ment in a place which is subjected to the direct air flow of
the unit.
¡ DO NOT ride or place objects on the unit.
¡ DO NOT turn the unit on its side or upside down.
1
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido