Troubleshooting
Ice
Refrigerator
is
leaking water
ice forms in inlet
tube to ice maker
Water flow is
smower than normal
• Plastic tubing was used to complete
water connection.
• Improper water valve was installed.
• Water pressure is low.
• Freezer temperature is too high.
• Water pressure is low.
• Improper water valve was installed.
The manufacturer recommends using copper tubing
for installation. Plastic is less durable and can cause
leakage. The manufacturer
is not responsible for
property damage due to improper
installation
or water connection.
Check water connection procedure (see page 8}.
Self-piercing and 3/,6.. saddle valves cause low water
pressure and may clog the line over time. The
manufacturer is not responsible for property
damage due to improper installation or water
connection.
Water pressure must be between 35 to 100 pounds
per square inch to function properly, A minimum
pressure of 35 pounds per square inch is
recommended for refrigerators with water filters,
Adjust freezer control (see page 10]. Freezer is
recommended to be approximately 0° F (-18° C).
Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Check water connection procedure in your
Installation Instructions. Self-piercing and 3/,_.. saddle
valves cause low water pressure and may clog the
line over time. The manufacturer
is not
responsible for property damage due to
improper installation or water connection.
Open water valve completely and check for leaks.
• Copper tubing has kinks.
• Turn off water supply and remove kinks. If kinks
cannot be removed, replace tubing.
• Water filter is clogged or needs to be
• Change water filter (see page 15}.