Use non-sparking components to mitigate the risk of spark and explosion in hazardous locations.
All electrical terminations shall be made according to Federal, State, and Local codes for hazardous
or classified locations.
All mechanical penetrations to the basin by cables or conduit shall be made according to
specification and best practices associated with hazardous locations.
Conduit, junction boxes, and associated components shall be approved for use with hazardous
locations and installed according to specifications.
Mechanical Installation Procedure
1. Record the pump model, serial number, manufacture date, and installation date on the front page of this manual.
2. Complete a visual inspection of the pump prior to installation. Address any loose fasteners and missing or damaged
parts. Contact Liberty Pumps with any concerns.
3. Complete an inspection of the tank or basin where the pump will be installed. Remove any construction debris or
foreign material from the vessel.
4. If the pump is to be installed using a guide rail and base, verify the installation is correct and that all mounting hard-
ware is tight.
5. Mount the guide rail claw components to the pump, being certain to tighten all fasteners as specified. Be sure all
gaskets and components are present.
6. For installations not using a guide rail, complete all pump mounted plumbing at this time being sure to use all neces-
sary sealants and hardware.
7. Place pump in basin, being sure the mounting interface (guide rail, torque stop, etc.) is engaged correctly.
8. Verify that all plumbing components in the tank or basin are installed correctly and that they are functional. Validate
that any valves are open and ready for pump use.
9. Set the floats heights to control pump operation. The minimum process fluid level for safe pump operation shall not
be less than 13 inches.
10. Complete any final connections to the pump.
11. Engage power to panel and pump
12. Run several cycles of water through the system to verify correct control operation for the installation. Be certain to
complete adequate testing, especially on systems with multiple pumps or custom control configurations.
WARNING
RISK OF FIRE - When working in a hazardous location, all precautions
to minimize ignition sources such as spark and flame should be
minimized to limit the potential for fire or explosion.
WARNING
RISK OF ELECTRIC SHOCK - Always disconnect the pump from
power source prior to handling, set-up, or maintenance.