with the intended temperature, voltage and power
ranges. The standards of the respective countries
apply.
DC versions:
Use shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance or con-
nect not used count inputs to ground (0 V).
AC versions:
Use shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance.
1.9 Operation
Is the device set and programmed correctly (function;
for counters, max. counting frequency)?
Overview
Model
Operating mode
6.130.012.8x0
Count
6.130.012.8x2
6.130.012.8x3
6.131.012.8x0
Cnt.Dir/Up.Dn
6.131.012.8x1
6.131.012.8x3
Up.Dn
6.132.012.8x3
Cnt.Dir
6.133.012.8x0
Quad/Quad2
6.133.012.8x1
Table 1
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A:
Counting input
INP B:
Counting direction input
1.10 Failure possibilities and causes
Impossible to use the keys:
- Key lock input activated
Counter does not count:
- Wrong or reversed wiring of the counting input
- Setting of an input signal not matching the pulse gen-
erator
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator
and the counter
- Maximum counting frequency exceeded
- Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce a
possibly existing defect and to repair your device as
quickly as possible.
Counting inputs
INP A
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC AC/DC 30 Hz
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
Options:
Up.Dn:
Quad:
Quad2:
INP B
07 kHz 00 ... 0,7 V DC
12 kHz
00 ... 0,7 V DC
10 ... 260 V AC/DC
07 kHz
00 ... 0,7 V DC
12 kHz
04 ... 30 V DC
30 Hz
10 ... 260 V AC/DC
30 Hz
10 ... 260 V AC/DC
03 kHz
00 ... 0,7 V DC
06 kHz
04 ... 30 V DC
x = 5: no backlight
x = 6: with backlight
Differential counting input
INP A:
Adding counting input
INP B:
Subtracting counting input
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
NPN
30 Hz
NPN
AC/DC
0–
NPN
07 kHz
PNP
12 kHz
AC/DC
30 Hz
AC/DC
30 Hz
NPN
03 kHz
PNP
06 kHz