A(mm)
760
WARNING: Ensuring Adequate Ventilation
Make sure the ceramic hob is well ventilated and that air inlet and outlet are not blocked. In order to
avoid accidental touch with the overheating bottom of the hob, or getting unexpectable electric shock
during working, it is necessary to put a wooden insert, fixed by screws, at a minimum distance of
50mm from the bottom of the hob. Follow the requirements below.
There are ventilation holes around outside of the hob. YOU MUST ensure these holes are not
blocked by the worktop when you put the hob into position.
• Be aware that the glue that join the plastic or wooden material to the furniture, has to resist to
temperature not below 150
• The rear wall, adjacent and surrounding surfaces must therefore be able to withstand an tem-
perature of 90
A
B
E E
B(mm)
50 mini
Max. 5mm
o
C, to avoid the unstuck of the paneling.
o
C.
C(mm)
20 mini
Min. 50mm
Max. 5mm
13
wall
D
Air intake
Min.30mm
E
Air exit 5mm