CircuitBreaker
ResetButton
Figure13
ServiceCenterif repairsare needed.
RESETTING
CiRCUiT
BREAKER
RESET
BUTTON
This moweris equippedwith an circuitbreakerreset buttonto prevent
overheating damageto the motor.
If the circuitbreakerresetbutton popsout:
1. Releasethe motor/bladecontrolhandleand do NOT re-startthe
mowerfor at least one minute,allowingfor the motortime to cool.
2. Press thecircuitbreakerreset button inwardto reset.See Figure
13.
If the circuitbreakerresetbutton popsout shortlyafter resetting:
1. Releasethe motor/bladecontrolhandleand do NOT re-startthe
mowerfor at least 15 minutesto allowthe motorextratime to cool.
2. Press thecircuitbreakerreset button inwardto reset.
3. Restart unit.
NOTE:If the circuitbreakerresetbutton popsout repeatedlyduring
operationor will notremainin whenattemptingto reset,contactyour
nearestSearsServiceCenterto arrangefor repair.
BATTERY
CARE
IMPORTANT: R eplacewith onlythe identicalbatteryprovidedwith this
mower(Part number725-04381).The batteryshouldonly be replaced
bya SearsServiceCenter.
MAINTENANCE
SCHEDULE
_,lways s top the motorand removekey beforecleaning,lubricating
_rperformingany repairsor maintenance on thelawn mower.Always
Near s afetyglassesduringoperation or whileperforming anyadjustments
_rrepairs.
Followthe maintenance schedulegiven below.This chart describes
serviceguidelinesonly.Use the ServiceLog columnto keeptrackof
completedmaintenancetasks.To locate the nearest Sears Service
Center or to schedule service, simply contactSears at
1-800-4-MY-HOME®.
EachUse
1.
Mowerblades
2.
Looseor missinghardware
3.
Controls
4.
Motor
5.
Deck
Annuallyor 25 hours
1.
Wheels
2.
Reardischargedoor and
side mulchplug
3.
Mowerblades
BeforeStorage
1.
Battery
DuringStorage
1.
Battery
1.
Sharpenas required
2.
Tightenor replace
3.
Checkfor properoperation
4.
Removeanybuildup of grassand
leaveson or aroundthe motorcover
(do not usewater).
5.
Clean undersideof deck with a
suitabletool (do notuse water).
1.
Lubewith lightoil
2.
Lubetorsionspringand pivot point
with lightoil.
3.
Sharpenand balance
1.
Fullycharge
1.
Chargeeverytwo months
14