E L E V A T I N G C U L I N A R Y E X C E L L E N C E
MAINTENANCE
BASIC, BIGBASIC, TOP, FASTTOP and BIGTOP
1. Remove the filter by lifting it slightly upwards and removing it
outwards with a frontal movement. Remove the peel buckets and
empty them.
2. Remove the drip tray and the down tubes by moving them to the
rear.
3. Unscrew the knobs that hold the cover and remove them. Remove
the cover. Unscrew the central knob and remove it together with
the splash guard
4. Extract the central blade by moving it forward.
ATTENTION! This piece contains a cutting element. Handle this
part with great care. Unscrew the four knobs that secure the
drums and squeezers of the juicing system and remove them.
Remove the two juicing squeezers and the two drums by moving
them forward. Also remove the feeder tube with a forward
movement.
5. Dismantle the Push system. Remove the knob at the bottom.
Press the button as far as possible and while holding it down,
extract the entire assembly with a forward movement of
approximately one centimeter, and when it stops, move down.
6. For TOP, FASTTOP and BIGTOP models: unscrew the knob that
secures the feeder plate and remove the feeder plate and feeding
basket. Clean all the parts perfectly, as well as the machine block
with water and detergent. The parts, with the exception of the
cover, can be put in the dishwasher at a maximum temperature
of 40ºC. Do not use abrasive products or solvents, as they could damage the compound of the elements
of the juicer system. Do not clean the juicer assembly using pressurized water. Dry the components of the
squeezing system and the machine block.
Page 16 / 72