To prevent a possible fire, keep the generator at least 1 meter away
from building walls and other equipment during operation. Do not place
flammable objects close to the engine.
Before beginning your pre-operation checks, be sure the generator is on
a level surface and the engine switch is in the OFF position.
Operating this generator less than 1 meter from a building or other
obstruction can cause overheating and damage the generator.
For proper cooling, allow at least 1 meter of empty space above and
around the generator.
Check the Engine
• Before each use, look around and underneath the engine for signs of
oil or gasoline leaks.
• Check the oil level (see page 33). A low oil level will cause the Oil
Alert system to shut down the engine.
• Check the air filter (see page 36). A dirty air filter will restrict air flow
to the carburetor, reducing engine and generator performance.
• Check the fuel level (see page 31). Starting with a full tank will help
to eliminate or reduce operating interruptions for refueling.
BEFORE OPERATION
19