Descargar Imprimir esta página

DeWalt DXCM20020US Manual De Instrucciones página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Breaking in the Pump
● Check and tighten all fittings.
● Turn the pressure regulator knob  (Fig. F) fully clockwise
to open the air flow.
● Place the switch  in the OFF (O) position (Fig. G) and
plug in the power cord.
Fig. G
● Open the drain valve completely.
Fig. H
Drain valve (closed)
● Turn the air compressor ON ( l ) and run the air compressor
for 10 minutes to break in pump parts.
● Place the switch  in the OFF (O) position.
● Close the drain valve.
LIFT AND TRANSPORT
Lift
● To lift the compressor, use the front handle only (A) or both
handles (A and B).
● We suggest you use a couple of straps wrapped around the
two handles as shown in fig. I.

WARNING: Do not attempt to lift the compressor
by yourself.

WARNING: Do not use the rear handle B alone
for lifting.

WARNING: Do not lift the unit by the pipes.
12

Fig. I
Transport
● You can use the front handle for pulling the unit (see Fig. J).

Drain valve
● When transporting the compressor, do not drop the unit or
(open)
Fig. J
WARNING: Do not touch the pipes as they are
very hot.
A
CAUTION: DO NOT try to pull the unit by the rear
handle.
allow the unit to fall from its vertical position.
B

Publicidad

loading