Descargar Imprimir esta página

Waeco AirCon Service Center BMW 2500G Instrucciones De Uso página 121

Estación de mantenimiento de aire acondicionado

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BMW 2500G
"R134a to system" indicates how many grams of refrigerant have been
filled into air conditioning systems using the menu item "Short selec-
tion" or "Free selection".
"Vacuum time" indicates how long the vacuum pump was operating in
total.
"Service completed" indicates the amount of service work performed on
the air conditioning service unit.
9.8
Correcting the filling quantity for long service
hoses
I
NOTE
 If longer or shorter service hoses are required for the device, you
need to adjust the filling quantities to the new hose lengths.
 The service hoses for the high and low pressure sides must always
be of the same length, as otherwise the filling quantities will not be
correctly measured.
1. In the basic menu, use the cursor keys  or  to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor keys  or  to select "Service":
4. Press ENTER to confirm.
EN
R134a to system
Total
g.
STOP-EXIT
Vacuum time
Total
min.
STOP-EXIT
Service completed:
Total
Total
STOP-EXIT
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
Service tasks
07/03/20
1200
07/03/20
79
08/03/20
4