CAUTION: These kits must be installed by a qualified installer or service technician.
306SR-A
Side Discharge on Casing
1.
Cut out and remove embossed area on
casing side.
2.
Remove knockout from inner liner.
3.
Place 1-1/2" boot from kit through
opening, matching flanges of boot to
knockout on inner liner.
4.
Mark screw holes and remove boot.
5.
Drill holes with a 1/8" drill.
6.
Attach inner boot with screws provided.
7.
Place grille into position, drill holes into
casing, and attach with screws provided.
FIG. 11
Plaster
Ground
1018028-C
306SR & 30SRB: SIDE DISCHARGE KITS (Optional Accessories)
30SRB-A
Side Discharge with Extension Boot
1.
2.
3.
4.
5.
6.
7.
8.
14-3/8"
10-3/16"
Cut opening in drywall as shown in figure 11, below.
Position plaster ground as shown in figure 11, below. (Optional).
Cut out and remove embossed section on casing side.
Remove knockout on inner liner.
Put heater into position.
Place inner boot into position, mark and cut boot flush with wall. Place outer
boot into position, mark and cut boot flush with wall.
Place boot trim into position, slide INNER BOOT through wall from adjacent
room and attach to inner liner. Slide OUTER BOOT through wall from
adjacent room and attach to casing side.
Place grill in position and secure to wall.
ROUGH-INS FOR
SIDE DISCHARGE KITS
Install plaster grounds as shown to the left.
NOTE: When side discharge Kit No. 30SRB is being used,
furnace should be set exactly 4" from side wall.
Page 16
NOTE:
Maximum boot
length is 10"