Troubleshooting
Problem
The display shows
"Not enough UV. Add!"
The display shows
"Not enough oil. Add!"
The display shows
"External tank empty or
closed valve. Check!"
The display shows
"Change the equipment
drier filter! Go on?"
The display shows
"Change the vacuum pump
oil! Go on?"
The display shows
"Printer not in line!
Carry on?"
The display shows
"Error 01"
The display shows
"Error 02"
The display shows
"Error 09"
138
Cause
This message appears dur-
ing the filling process if there
is not enough UV additive in
the container to finish the
process.
Message that appears during
the filling process if there is
not enough fresh oil in the
container to finish the pro-
cess.
Message that appears at the
start or during the filling of
the internal refrigerant con-
tainer if the set refrigerant
quantity cannot be attained.
This message appears when
you switch on the
AirConServiceCenter.
This message appears when
you switch on the
AirConServiceCenter.
Message indicates a printer
fault.
Refrigerant was added
before draining was com-
pleted.
The air conditioning system
is leaking. There is still refrig-
erant in the air conditioning
system.
Low pressure connector not
connected to the flush con-
tainer during flushing.
BMW5500G RPA
Remedy
Fill the UV additive container.
Top up the fresh oil container
with a suitable oil type.
Check if the external refriger-
ant container still contains
enough refrigerant or if the
valves of the external refrig-
erant container are open.
Change the internal filter as
soon as possible (see chap-
ter "Changing the dryer filter"
on page 122).
To skip this, press ENTER
for 3 seconds.
Change the vacuum pump oil
as soon as possible (see
chapter "Changing the vac-
uum pump oil" on page 127).
To skip this, press ENTER
for 3 seconds.
Check if there is paper in the
printer.
Check if the printer is
switched on (yellow LED
must light up constantly).
Check that the cover is
closed properly.
Repeat the draining proce-
dure; do not interrupt it this
time.
Fix the leak.
Connect low pressure hose
to the flush box and open
valve.
EN