Descargar Imprimir esta página

DeWalt DW448 Manual Del Usuario página 19

Amoladora angular

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Description (fig. A)
Your Angle Grinder has been designed for
professional grinding and cutting applications.
Sanding requires a special rubber backing pad
available as an option.
1 ON/OFF-switch
2 Lock-off button
3 Lock-on button
4 Side handle
5 Guard
6 Spindle lock
7 LED indicator [DW451(K) & DW458(K)]
DW451(K) & DW458(K) - Soft Start Feature
The soft start feature allows a slow speed build-up
to avoid an initial jerk when starting. This feature is
particularly useful when working in confined spaces.
DW451(K) & DW458(K) - Constant Speed Control
Feature
The constant speed control feature maintains tool
speed under load to assure optimum efficiency and
productivity. It also functions as an overload feature.
DW451(K) & DW458(K) - Overload Indication
When the red LED (7) on top of the tool lights up
under load, the motor is being strained.
For optimum efficiency and to avoid damaging the
motor, the tool should be operated so that the
indicator does not light for long periods.
Electrical safety
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 50144; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
17
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor size
2
is 1.5 mm
. When using a cable reel, always unwind
the cable completely. Also refer to the table below.
2
Conductor size (mm
)
0.75
1.00
1.50
2.50
4.00
E N G L I S H
Cable rating (Amperes)
6
10
15
20
25
Cable length (m)
7.5
15
25
30
45
.
60
en - 4

Publicidad

loading