8 UNPACKING
Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
• Remove the packaging.
nels. Use a suitable solvent to remove any residual adhesive
from the panels.
9 POSITIONING
• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
APPLIANCE ASSEMBLY WITH BASE
Follow the instructions provided with the type of support utili-
zed.
JOINING APPLIANCES TOGETHER IN LINE
• Place the appliances side by side and adjust the tops to the
same height.
• Unite the appliances using the special unionjoint-coverings
supplied upon request
10 FUMES EXHAUST SYSTEM
Provide a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance dataplate.
APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed.
APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood.
APPLIANCE TYPE "B11"
from the appliance manufacturer. Follow the assembly in-
stant to 300°C.
must not exceed 3 metres.
11 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
CONNECTION TO THE GAS SUPPLY
Check the compatibility of the gas supply. Check the details
given on the decals on the packing and on the appliance.If
necessary, convert the appliance to the type of gas utilized.
Follow the instructions in the next paragraph "Conversion to a
the appliance in an easily accessible position.
• Do not use connection pipes having a diameter smaller than
that of the appliance's gas connector.
6
• Once the appliance has been installed, check for leaks at the
connection points.
ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the voltage
-
and frequency of the power supply present on site. Check the
details given on the appliance data plate.
If used, the symbol
CAUTION - HAZARDOUS VOLTAGE.
• Install an adequately rated omnipolar circuit-breaker upline
of the appliance in an easily accessible point, in compliance
with installation regulations; the circuit breaker must guaran-
tee immediate omnipolar disconnection from the mains, with
a minimum contact opening that allows complete disconnec-
tion in overvoltage category III conditions. The maximum per-
mitted current dispersion is 1mA/kW.
ble which is oil resistant, type H05RN-F or H07RN-F, for ca-
ble size consult the technical data table.
• Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied with the appliance.
• Secure the power supply cable with the cable clamp.
• Protect the power supply cable on the outside of the applian-
ce with a rigid plastic or metal pipe.
• If the power supply cable is damaged, it must be replaced
by the manufacturer or the technical after-sales service or,
any risk whatsoever.
PROTECTIVE EARTH AND EARTH BONDING CONNEC-
TIONS
earth conductor to the terminal with the symbol
next to the main terminal board.
Connect the metal structure of the electrical appliance to the
equipotential node. Connect the conductor to the terminal with
the symbol
on the outside part of the bottom.
• This symbol indicates that the appliance must be included in
an equipotential system connected in compliance with cur-
rent regulations.
12 CONVERSION TO A DIFFERENT TYPE OF GAS
-
• which gas can be used for the appliance.
• the nozzles and settings for each gas that can be used.For
nozzles, the number indicated in table T1 is also stamped on
the nozzle body.
To convert the appliance to the local gas type, follow the in-
structions given in a table T1 and carry out the steps below:
• Replace the main burner nozzle ( UM ).
• Adjust the main burner's air regulator to distance A.
• Replace the pilot burner nozzle ( UP ).
• Replace the gas valve minimum nozzle ( Um ).
nozzles and adhesive tabs are supplied with the appliance.
REPLACING THE MAIN BURNER NOZZLE AND ADJU-
STING THE PRIMARY AIR FLOW.
• Slacken screw V.
with the one indicated in table T1.