Operating manual
MULTI-CHARGER CONFIGURATION ̶ PARALLELIZATION (PARALLEL)
When identical Gysflash CNT chargers are connected in parallel, the SHM handles comunication between them in
order to become an ultra-powerful charging system.
Communication
SHM
Master
I1
To use this function, the SHM must be combined with a Power Hub Module (PHM - ref. 056589) to manage
the power.
Paralleling can only be done with identical GYSFLASH CNT units (maximum 4).
Master/Sl ave co mmu nicatio n:
Gysflash CNT chargers are installed in parallel using a Master/Slave configuration.
 One Gysflash (the Master) controls all the others (the Slaves).
Set up
1. Connecting the Gysflash to the SHM:
Connect the Gysflash units you wish to run in parallel to a channel on the SHM.
The Master G ysflas h must be connected to channel
The Slave Gys flashes units can be connected to channels
Make sure that the Gysflash output cables are properly interconnected via the PHM.
For more detail, refer to the PHM manual.
For Gysflash units manufactured before January 2024 (serial number less than 24.01.xxxxxx.
xxxxxx), please refer to the «SHM supplementary leaflet» available on the website www.gys.fr for
more details on the specific installation requirements for this version of charger.
Translation of the original
instructions
Slave 1
I2
PHM
Power
1
Slave 2
I3
I4
I1 + I2 + I3 + I4
(FIG II).
2
,
3
, or
4
(FIG II).
SMART HUB MODULE
Slave 3
System being
supplied