Troubleshooting
5�1
Installation of the pump
1. Connect the pressure line.
2. Connect the power cable.
The pump can be suspended by the handle
and positioned slightly above the ground. De-
pending on the pump capacity, a possibly high
start-up jerk of the pump must be observed
here!
5�2
Check direction of rotation
The correct direction of rotation of the pump
is given when the start-up jerk is in counter-
clockwise direction (as seen from above).
If the direction of rotation is wrong, two of the
phases must be reversed (400 V) (have this
work done by a qualified electrician).
397
46 /
6
Risk of crushing or drawing in at the rotor
Danger of cutting injuries when reaching
into the impeller
f
f
Operating Instructions for Submersible Pump Series SPT-R
Troubleshooting
WARNING
Disconnect the pump from the power
source before performing any repair or
troubleshooting work.
Secure the pump against accidental
switch-on.