Invalid arm
Current too low
Insufficient air pressure
Pump priming
Self-diagnostic
Line
Comment
no.
1
Name of the product
2
Product serial number
3
Secondary soft version
4
Hard primary version
5
Primary soft version
6
Keyboard test
7
Communication test µ
8
SD card
9
Voltage phase 1
10
Voltage phase 2
11
Voltage phase 3
MI300T 220V
The arm used is not compatible with the welding mode selected.
1/ Check the weld
If the current obtained during a spot weld is lower than the expected value (6%), the machine dis-
plays the warning message «Low current, check the weld».
2/ Check the sheets
If the machine cannot deliver the current required, the error message «Low current, check the
sheets» is displayed. The weld does not happen and the fault must be skipped for the weld to happen.
The «Pump priming fault» message appears when the cooling system pump is defused. Check the
coolant level in the tank.
Display right
Display left column
column
Page CHECK n°1
MI300T
PASS
SN xx.xx.xxxxxx.xxxxxx
PASS or FAIL
CONTROL SOFT Vxx.
PASS
xx.xx
ALIM HARD 400V
PASS or FAIL
ALIM SOFT Vx.xx
PASS, FAIL
KEYBOARD
PASS or FAIL
COMMUNICATION
PASS or FAIL
SD xx.xx.xx.xx.xxxx
PASS or FAIL
U12 = xxx V
PASS or FAIL
U23 = xxx V
PASS or FAIL
U31 = xxx V
PASS or FAIL
If the input pressure is insufficient to deliver the tightening requested,
the machine beeps and displays, before the weld, the error message
«Insufficient air pressure».
Pressing the trigger a second time is used to «force» the spot weld
using the available pressure. If the tightening recorded is insufficient,
the machine displays «Low pressure».
«p low» is also recorded in the active report.
When the power is turned on, the machine performs self-diagnostics
and displays the results on the screen.
If no blocking error is present, this page is displayed for 3s and then
disappears. During this period, a short press of the MODE buttons, ▲
or ▼, leaves the CHECK pages displayed (results summarized on two
pages). A long press on MODE will exit the CHECK mode.
It is not possible to exit the CHECK pages if a blocking fault is detected,
except for a phase failure (see list below).
Type of defect
In the event of a blocking fault
No blocking
No blocking
No blocking
Blocking
Wrong power supply card, contact your dealer.
Blocking
Wrong software version, contact your reseller.
Make sure that no key on the keypad or trigger is pressed, if
No blocking
the fault persists contact your dealer.
Communication problem between the cards, contact your
Blocking
No blocking
Blocking
If there is no phase, pressing MODE for 5s accesses the Setup
Blocking
menu and allows the machine to operate in Showroom mode.
Blocking
EN
retailer.
SD card not present.
29