q j
12
CAPA voltage
13
Voltage PM IGBT 1 and 2
14
Voltage PM IGBT 3 and 4
15
IGBT test result 1
16
IGBT test result 2
17
IGBT test result 3
18
IGBT test result 4
1
Name of the product
Test result primary detec-
2
tion transfo
3
Date and time
4
SHOW-ROOM mode
Welding trigger, gun
5
trigger and gun tempera-
ture test
Trigger test on diode ope-
6
ning and temperature
Transformer primary
7
temperature
8
Position sensor
9
Welding voltage
10
Backup battery voltage
11
Clamp pressure
12
Détection présence pistolet
SPOT COUNT
If the caps are not changed after the warning message is displayed and the count is simply reset, they can deteriorate and have a negative
impact on the quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings» menu.
If the identification mode is switched off, il suffit de saisir un nom de rapport et de l'activer pour mémoriser les points de soudure effectués.
The log allows to store the parameters of the spots made using the clamp. It is available in all the modes by pressing the 2 buttons
The user program is available in all modes by pressing the
30
MI300T 220V
UPMCAPA = 0 V
PASS
UPMIGBT12 = xxx V
PASS or FAIL
UPMIGBT34 = xxx V
PASS or FAIL
IGBT1 = xxx V
PASS or FAIL
IGBT2 = xxx V
PASS or FAIL
IGBT3 = xxx V
PASS or FAIL
IGBT4 = xxx V
PASS or FAIL
CONNEXION TRANSFO
PASS or FAIL
DATE/TIME
PASS or FAIL
SHOW-ROOM
ON or OFF
GGUN WELD SW =
PASS
x.xx V
GGUN OPEN SW = x.xx V
PASS or FAIL
TRANSFO TEMP = x.xx V
ON or OFF
THICKNESS SENSOR =
PASS
xx.x mm
WELDING VOLTAGE =
PASS
x.xx V
BACKUP CELL = x.xx V
PASS or FAIL
AIR PRESSURE = xx.x
bar si PASS
PASS or FAIL
Network pressure
GUN PRESSURE = xx.x
bar si PASS
PASS or FAIL
Gun presence detection
CONNEXION GUN
ON or OFF
A spot count tool keeps count of the different spot weld done using the same cap. If there is no
problem during the welding, the following message is displayed.
The count is displayed at the top left corner of the screen. Press the button
reset the count after changing the caps.
The machine counts the number of points achieved with each arm independently. A warning
message appears on the screen when the limit of the points made by the headings is reached. The
message remains displayed after each point until the counter is reset.
and
No blocking
Blocking
Blocking
Blocking
Problem controlling the power electronics, contact your
Blocking
Blocking
Blocking
Page CHECK n°2
Check the connection of the power cable from the gripper to
Blocking
No blocking
No blocking
No blocking
Blocking
Check the connection of the power diode temperature sensor.
Overheating of the power transformer. Allow the machine to
Blocking
No blocking
No blocking
No blocking
Blocking
Air pressure sensor from the HS network, contact your dealer.
Blocking
Air pressure sensor of the HS gripper, contact your dealer.
No blocking
buttons.
dealer.
the generator.
cool down before starting up again.
for 2 seconds to
EN
and
.