ENGLISH
EN
Notes on operation, Care and maintenance
WARNING
Before doing any work on the machine, pull the plug out of the socket.
Check all connected cables on a regular basis.
If power tools are damaged, they must be immediately removed from use.
Repairs must always be referred to a Weller-trained
specialist.
Use original replacement parts only.
WARNING
External Power Supply:
Mount plug type appropriate for your region by slipping into the power adapter
until the plug clicks in.
To ensure that the filtration system functions properly, the filter must be
replaced as follows
• at least once a year or
• when indicated or
• if the maximum allowable workplace concentration is exceeded or
• as per maintenance schedule
The suspended matter filter and the broadband gas filter are complementary
to one another and can be replaced together as a compact filter. The compact
filter must be changed once a year in order to ensure it is fully functional. The
fine dust filter (filter mat) is the preliminary stage of the compact filter and
therefore must be replaced more frequently.
It is strongly recommended that the compact filter be replaced after no more
than 10 fine dust filter changes.
The red warning light is flashing
Recommended service life of filter has expired.Indicates that the filter needs
changing. Reset the warning with the reset function on the control panel and
schedule a filter change.
The red warning light is lit continuously
Extraction capacity is too low. Switch off the filter unit. Check the nozzles and
tubes, and clean them if necessary. If the red warning light comes on again the
next time the unit is turned on, the filter must be changed.
NOTICE
Different fluxes and flux constituents and the amount of and size of dust
particles in the extracted air will signifi cantly effect the filters working life.
Submicron particles in the extracted air increase when soldering or welding to
varnish insulated wire.
CAUTION!
Contaminated filters must be treated as special waste.
Dispose of replaced equipment parts, filters or old devices in accordance
with the rules and regulations applicable in your country.
Message/symptom
Possible cause
• Extraction power
• Filter is dirty
missing
• RGB light turns
• Incorrect supply
blue when turned
voltage.
on.
• RGB light blue
• The blower is
during operation
blocked.
18
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Warranty
Claims by the buyer for physical defects are time-barred after a period of one
year from delivery to the buyer. This does not apply to claims by the buyer for
indemnification in accordance with §§ 478, 479 BGB (German Federal Law
Gazette).
We shall only be liable for claims arising from a warranty furnished by us if the
quality or durability warranty has been furnished by use in writing and using the
term „Warranty".
The warranty shall be void if damage is due to improper use and if the device
has been tampered with by unauthorized persons.
For more information please visit
www.weller-tools.com.
Technical Data
Technical Data
Dimensions L x W x H
Mains supply voltage
Operating voltage
Power consumption
Weight
Safety class
Combined filter
Maximum vacuum
Maximum quantity supplied (m³/h) 26
port
Operating sound level from
1 m distance
Power supply
Model name: DZ048BHL240200H
Manufacturer's name: GUANGDONG KEERDA ELECTRONICS CO., LTD
Input voltage
Input AC frequency
Output voltage
Output current
Output power
Remedial measures
Average active efficiency
• change the filter
Efficiency at low load (10%)
No-load power consumption
• Check the power
supply.
Subject to technical alterations and amendments.
• Disconnect the
Zero Smog Shield Pro
device from the
ESD-compatible design and ESD-compatible workstation.
power supply.
Before performing work of any kind on the unit, always disconnect the power
Contact the service
plug from the socket.
center if necessary.
Zero Smog
Zero Smog
Shield
Shield Pro
(mm )
269.5 x 212 x 110
269.5 x 212 x 110
(inch)
10.6 x 8.3 x 4.3
10.6 x 8.3 x 4.3
(VAC)
100-240
100-240
(Hz)
50/60
50/60
(VDC) 24
24
(W)
10
20
(kg)
2
2
III
III
E10 EPA /
E10 EPA /
Activated carbon
Activated carbon
foam
(Pa)
285
490
32
-
RS232
dBA
50
59
at maximum
speed
(V)
100-240
(VAC)
100-240
50/60
(Hz)
(V)
24
(A)
2
(W)
48
(%)
87.76
(%)
88.1
(W)
0.09