Descargar Imprimir esta página

Teka TNL 6401 Manual Del Usuario página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
indicate a greater distance these must be
observed.
To achieve optimum performance the length of
the outlet hose should not exceed 4 meters, or
include more than two 90º angles (elbows).
Although
venting
recommended, activated carbon filters may be
used, which allow the gas to be returned to
the kitchen through the outlet pipe.
Before seeking technical assistance carry out the following checks first:
Defect
The extractor does not
work
The extractor does not
blow enough or vibrates
The lamps do not light
Height above gas hob: 75 mm minimum.
NEVER PLACE THE COOKER HOOD OVER
AN EYE-LEVEL GRILL.
This appliance is not intended for use by
young children or infirm persons without
supervision.
We
recommend
connected by a qualified electrician, who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
Should the colour of the wires in the mains
lead for the appliance not correspond with the
coloured markings identifying the terminal in
your spur box proceed as follows:
22
to
the
outside
Possible cause
The cable is not connected
No current is reaching the plug
Filter saturated with grease
Outlet obstructed
Inadequate air conduit
Lamp broken
Lamp Loose
that
the
appliance
If you wish to exchange the front for one
matching the kitchen units, follow the following
instructions (Fig. 3):
• Withdraw the movable group.
• Remove the screws (T) that support the
front.
is
• Install the new front fixing it with the same
screws that held the old one.
Connect the mains cable
Revise/repair the electricity circuit
Clean or substitute the filter
Eliminate obstructions
Contact the installer and follow instructions of this
manual
Exchange the bulb
Tighten bulb
This appliance must be connected by a
competent person, using fixed wiring via a
DOUBLE POLE SWITCHED FUSED SPUR
OUTLET.
Young children should be supervised to
ensure that they do not play with the
appliance.
is
The wire which is coloured blur must be
connected to the marked N (Neutral) or
coloured Black.
The wire which is coloured brown must be
connected to the marked L (Live) or couloured
Red
Where avialable (see installation), the wire
which is coloured yellow/green must be
connected to the market ⊥ or coloured
Yellow/Green.
Solution

Publicidad