Failure
The tool has too slow rota-
tions or it does not start
The tool starts and then
slows down
Insuffi cient power
Replacement parts
In order to obtain the information on spare parts for pneumatic tools, you must contact the manufacturer or its representative.
After completion of the work, the housing, ventilation slots switches, should be cleaned, for example, by air stream (pressure not
more than 0.3 MPa), with a brush or dry cloth without chemicals and cleaning fl uids. Tools and handles should be cleaned with
a dry, clean cloth.
Worn tools are secondary raw materials, it is forbidden to dispose of them together with household waste. because they contain
substances harmful to human health and the environment! Please actively support the cost-eff ective management of natural
resources and environmental protection by passing the used equipment to the point of storage for worn out devices. To reduce the
amount of disposed waste it is necessary to re-use them, recycle or recover in another form.
O R I G I N A L
14
Possible solution
Let a small amount of WD-40 through the air inlet. Run the tool for a few seconds. The blades may stick to the rotor. Run the tool for
about 30 seconds. Lubricate the tool with small amount of oil. Attention! The excess of oil can cause a decrease in power of tool. In this
case, you should clean the drive.
The compressor does not provide proper air supply. The tool starts by the air collected in the tank of compressor. As the tank is empty-
ing, the compressor has not kept pace with the refi lling of air shortages. Connect the device to a more effi cient compressor.
Make sure, that your hoses have an internal diameter, at least such as it is specifi ed in the table in paragraph 3. Check the set point of
pressure, whether it is set to the maximum value. Make sure, that the tool is properly cleaned and lubricated. In the absence of results,
you should pass the tool for repair.
EN