Descargar Imprimir esta página

Ingersoll Rand THOMAS AP-40 Manual De Instrucciones página 2

Bombas de membrana lineales

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 141
YP-VC,YP-A, LW model series specification
PNEUMATIC DATA
Description
Part number
Flow at rated pressure
Rated pressure
Operating range
ELECTRIC DATA
Motor type
Voltage
Power consumption ata rated pressure
Max current
GENERAL DATA
Ambient temperature
Weight
Inlet/Outlet diameter
Average sound level
Max sound level
SERVICE PARTS
Chamber block set
Air filter and gasket kit
Air filter kit
Protective switch
AP, LP model series specification
PNEUMATIC DATA
Description
Part number
Flow at rated pressure
Rated pressure
Operating range
ELECTRIC DATA
Motor type
Voltage
Power consumption ata rated pressure
Max current
GENERAL DATA
Ambient temperature
Weight
Inlet/Outlet diameter
Average sound level
Max sound level
SERVICE PARTS
Chamber block set
Air filter and gasket kit
Air filter kit
Protective switch
YP-40VC
52500402
40 l/min
-120 mbar
-50 to -200 mbar
Linear drive
230V 50Hz
43W
0.53A
-10 to 40°C
5.3Kg
Rc 3/8
39 dB(A)
50 dB(A)
700020
AP-40
52500453
46 l/min
120 mbar
50 to 200 mbar
Linear drive
230V 50Hz
0.34 A/ 29 W
0.38A
-10 to 40°C
4.3Kg
18 mm
34 dB(A)
35 dB(A)
700580
700582Y
7005983Y
YP-70VC
52500073
70 l/min
-180 mbar
-50 to -200 mbar
Linear drive
230V 50Hz
84W
1.16A
-10 to 40°C
6.2Kg
Rc 3/8
48 dB(A)
62 dB(A)
700038
AP-50G
52500001
47 l/min
200 mbar
100 to 300 mbar
Linear drive
230V 50Hz
0.29 A/ 31 W
0.35A
-10 to 40°C
5.8Kg
18 mm
34 dB(A)
42 dB(A)
700608
700582Y
700583Y
YP-70VC
60 l/min
-180 mbar
-50 to -200 mbar
Linear drive
115V 60Hz
89W
2.3A
-10 to 40°C
6.2Kg
Rc 3/8
41 dB(A)
62 dB(A)
AP-60G
52500002
60 l/min
200 mbar
100 to 300 mbar
Linear drive
230V 50Hz
0.39 A/ 41 W
0.45A
-10 to 40°C
5.8Kg
18 mm
34 dB(A)
42 dB(A)
700608
700582Y
700583Y
2

Publicidad