INDICATIONS ON THE DISPLAY (D1)
Start up display
(shown for 2 seconds):
"870" = firmware model;
"_20" = firmware version.
Indicates the dip-switch configuration
memorisation stage.
Alarm indications
FRA/FRC simultaneously activated
FCA/FCC simultaneously activated
FRA/FCA simultaneously activated or
FRC/FCC simultaneously activated
Block caused by opening the access door
or flip-back hood. Pressing the PROG button
will display the number of manoeuvres and the
security device status alternately.
During programming, this alarm indicates
excess time between one travel limit and
the over: turn off the power to the control unit,
check the travel limits, turn the power back on
and reprogram the control unit.
EEPROM memory error
Block during programming
This occurs when an NC contact is activated
(TB, FTCI, CSP) o when a blackout occurs
during programming. Once the passive state
of the security device has been reset the boom
will start to move automatically.
Operational indications
Pause time programming
Automatic programming under way
Serial line communication (CSER) activated
(only for diagnostics)
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating
(only during programming)
Opening with sensor compensation
Closing with sensor compensation
Test mode
Battery mode with a fully charged battery
Battery mode with a partially charged battery
Block caused by a flat battery
29