GB
MAS Silent
5. Clean the compressor if necessary (see
Chap. 2.6.3).
6. Depressurise the compressor (see Chap.
2.6.2).
2.6
Maintenance
Observe the safety instructions!
Interval
Daily
Once after 10 h
50 h
500 h
1,000 h
2,500 h
2.6.1 Service kits
We offer the following service kits that are suitable for periodic maintenance:
Con-
tents:
II/16
No later than
Tasks
As needed
Clean compressor
3/2-way valve
Commissioning
Check the oil level, add oil if necessary.
Check screw connections
Weekly
Check intake filter
Checking the water separator with filter
After 6 months
Check V-belt tension (where applicable)
Clean intake filter
Change oil (1st oil change)
Cleaning the condensate evaporator
After 1 year
Change oil (mineral oil)
Change intake filter
Replacing the condensate evaporator filter
mat
Change check valve and insert
Check screw connections
After 2 years
Change oil (synthetic oil)
Change V-belts (where applicable)
After 5 years
Change safety valve
MAS service kit
Interval
Filter mat
V-belt
Safety valve
Intake filter
Check valve insert
Dirt arrester screen
7. Transport the compressor to the storage
location (see Chap. 2.4.1).
1
2
500 h
1,000 h
2,000 h
X
X
X
X
X
X
X
X
X
X
X
X
See
chap-
ter
2.6.3
2.6.4
2.6.5
2.6.12
2.6.7
2.6.8
2.6.9
2.6.7
2.6.6
2.6.10
2.6.6
2.6.7
2.6.10
2.6.11
2.6.12
2.6.6
2.6.9
2.6.13
3
4
2,500 h 5,000 h
X
X
X
X
X
X
X
X
X
X
X
X