STEP 1 INSTALL THE HOOD
1. Confirm the damper is in place in the hood
exhaust opening, see previous page for
instructions.
2. Insert the hood into the cabinet opening.
3. Fasten with 8 screws [(A), (L) or (D) as needed],
4 in the front and 2 on each side, toward the
back of the hood. It is recommended to start
with one corner and fasten screws diagonally to
ensure unit flushness with cabinet.
4. Once the hood is in place, seal the duct to the
hood with duct tape (Do not use screws).
14
Installation
ELECTRICAL CONNECTION
1. Remove the electrical junction box cover.
2. Remove the electrical box knockout.
3. Feed the Power Supply Cable through the hole
and secure with a strain relief.
4. Attach the white lead of the power supply (A) to
the white lead of the range hood (D) with a wire
nut. Attach the black lead of the power supply (B)
to the black lead of the range hood (C) with a wire
nut. Connect the house ground wire under the
green grounding screw (E).
House Wiring
C
Hood Wiring
5. Reattach the electrical junction box cover.
Electrical Box
Knockout with
Strain Relief
E
B
A
D
49-2000894 Rev. 4