6c. Installing and starting up the temperature probe
Always begin the calibration procedure with a calibration reset.
Please contact your reseller to configure the temperature probe.
1
Open the cover, connect the temperature probe to
the °C terminal using a cable gland (see section 3C
and 3D) and close the cover.
2
Configure the temperature probe in the service
menu. Follow the procedure shown here and contact
your installer.
3
The temperature value appears in the top-right
corner of the screen.
1
Temperature probe calibration: Allows you to set
the probes to 1 point.
2
Manual calibration.
3
Without taking the probe out of the water, use the Up/
Down arrows to adjust the measurement displayed so
that it coincides with the reference value.
Activation of the temperature probe gives access to
the Smart filtration mode.
6d. Installing and starting up a heat pump
Please contact your reseller for installation and configuration of a heat pump.
1
Open the cover, and plug the heat pump cable into terminal AUX4 using a cable gland (see paragraph 3C and 3D) and close the cover again.
1
2
3
Enter the Service menu from the configuration menu.
4
Enter the password (contact your reseller for the password).
5
Enter the Extra settings menu.
6
Select the Heat menu
Activation of a heat pump gives access to the Heating and Intelligent filtration modes.
6e. Installing and starting up the free chlorine option (amperometric sensor)
Always begin the calibration procedure with a calibration reset.
We recommend calibrating the free chlorine sensor with a high chlorine level: between 1ppm and 1.2ppm.
1
Open the cover and connect the
CL CHIP card to the CL slot (see
section 3C). The chlorine reading
and the Measures menu will be
displayed automatically to configure
the setpoint and carry out the
calibration.
2
Place the sensor in a bypass,
following the sensor instructions.
3
Connect the 3 cables of the floater
to the extension circuit board (see
section 3C).
4
Connect the 2 cables of the sensor
to the extension circuit board (see
section 3C).
1
1
3
4
5
Start sensor calibration.
i
The flow through the transparent
mount must be constant to ensure
optimum reading.
i
The sensor has a lifetime of 1 year.
We recommend calibrating it once
a month during the season the pool
is in use
AquaRite
UV LS
®
Only use spare parts supplied by Hayward brands
2
3
2
5
6
7
Press Relay config.
8
Keep pressing until you select AUX4.
9
In the Filtration menu, the Heating and Intelligent modes will appear
automatically. Please select and configure one of the 2 modes.
1
Page 17 on 22
®
4
5
3
7
2
3
6
8