• If you would like to force the end of the cycle, press and hold
the button " " for three seconds (VII).
• Acoustic alarm will activate after end of counting down (VIII).
If alarm will not be turn off, time will continues counting time
(IX).To turn off alarm press any button.
Calibration (Fig. 2B on page 3)
• Turn off the appliance.
• Press and hold buttons "-" and "+" at the same time - cali-
bration screen will be displayed.
• Adjust the value pressing button SET and buttons "-" or "+".
• Turn appliance off and on again.
Cleaning & maintenance
• ATTENTION! Always disconnect the appliance from the pow-
er supply and cool down before storage, cleaning & main-
tenance.
• Do not use water jet or steam cleaner for cleaning and do not
push the appliance under the water as the parts will get wet
and electric shock might be resulted.
• If the appliance is not kept in a good state of cleanliness, this
can adversely affect the life of the appliance and result in a
dangerous situation.
Cleaning
• Clean the cooled exterior surface with a cloth or sponge
slightly dampened with a mild soap solution.
• For reasons of hygiene, the appliance should be cleaned be-
fore and after use.
• Avoid water contacting the electrical components.
• Never immerse the appliance in water or other liquids.
• Never use aggressive cleaning agents, abrasive sponges, or
cleaning agents containing chlorine. Do not use steel wool,
metallic utensils, or any sharp or pointed objects for clean-
ing. Do not use petrol or solvents!
• No parts are dishwasher safe.
Maintenance
• Check the operation of the appliance regularly to prevent se-
rious accidents.
• If you see that the appliance is not working properly or that
there is a problem, stop using it, switch it off and contact the
supplier.
• All maintenance, installation and repair work must be car-
ried out by specialised and authorised technicians, or recom-
mended by the manufacturer.
Transportation and Storage
• Before storage, always make sure that the appliance has
been disconnected from the power supply and completely
cooled down.
• Store the appliance in a cool, clean and dry place.
Error code identification
(Fig.4 on page 4)
Fig.
Possible cause
4.I.
Water level low.
4.II.
Power outage
during cycle.
Possible solution
Fill container do minimum level.
Appliance returned to current
status. Press any button.
4.III.
Err 1: Stirrer
motor.
4.IV.
Err 2: Overheat-
ing.
4.V.
Err 3: Thermal
probe.
4.VI.
Err 4: Improper
water heating.
Warranty
Any defect affecting the functionality of the appliance which
becomes apparent within one year after purchase will be re-
paired by free repair or replacement provided the appliance has
been used and maintained in accordance with the instructions
and has not been abused or misused in any way. Your statutory
rights are not affected. If the appliance is claimed under war-
ranty, state where and when it was purchased and include proof
of purchase (e.g. receipt).
In line with our policy of continuous product development we
reserve the right to change the product, packaging and docu-
mentation specifications without notice.
Discarding & Environment
When decommissioning the appliance, the prod-
uct must not be disposed of with other household
waste. Instead, it is your responsibility to dispose
to your waste equipment by handing it over to a
designated collection point. Failure to follow this
rule may be penalized in accordance with applicable regula-
tions on waste disposal. The separate collection and recycling
of your waste equipment at the time of disposal will help con-
serve natural resources and ensure that it is recycled in a man-
ner that protects human health and the environment.
For more information about where you can drop off your waste
for recycling, please contact your local waste collection compa-
ny. The manufacturers and importers do not take responsibility
for recycling, treatment and ecological disposal, either directly
or through a public system.
Make sure that the mains voltage
is correct.
Contact an authorised technician
service.
Check that appliance is well
ventilated and ambent temperature
is below 40°C.
Check that there is no heating
source near the appliance.
Check that the ventilation openings
are free from obstacles.
Check fan: Turn off appliance, wait
5 min. to cool down and turn it on
again. If fan not working - contact
an authorised servise.
Contact an authorised technician
service.
Make sure that the mains voltage
is correct.
Contact an authorised technician
service.
GB