7.1 System parameters
7.1.1 FOx
Function Output (switching function of the outputs 1/2)
1
Relay energised (transistor output switched) when the current value is below the
switch point SPx (signalled state: "minimum speed"/"blocked")�
2
Relay de-energised (transistor output blocked) when the current value is below the
switch point SPx (signalled fault: "underspeed "/"blocked")�
3
Relay energised (transistor output switched) when the current value is above the
switch point SPx (signalled state: "rotational speed reached")�
4
Relay de-energised (transistor output blocked) when the current value is above the
switch point SPx (signalled fault: "overspeed")�
5
Relay is energised (transistor output switched) within a frequency range (acceptable
range)�
6
Relay is de-energised (transistor output blocked) within the frequency range� With the
functions 5 and 6 a frequency range above and below the switch point SPx is defined
in connection with the parameter HYx (hysteresis)�
SPx = (f
+ f
) ÷ 2
max
min
HY = ((SP - SP
) ÷ SP) x 100 [%]
min
Values
Default settings
7.1.2 SOx
Store Output (latching function outputs 1/2)
When this parameter is active, the respective output does not switch back automatically
but must be reset�
Values
Default value
Instrucciones de montaje y funcionamiento – Accionamiento de elevador de cangilones – Serie X..e
1���6
FO1 = 2
FO2 = 3
0 = inactive
1 = front reset ([Enter/►] > 3 s)
2 = front reset and external reset
0 (inactive)