Descargar Imprimir esta página

RIB T2 KING 24V Manual De Instrucciones página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN
5 SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE),
THEREBY COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453).
IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY
POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed).
Adjustment of the automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes
the voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment
is performed to determine the correct speed at the end of opening and closing according to
the gate or when there is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT
ACTIVATED and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing.
Only with gate completely (total) or partially (pedestrian) open and LED DL6 on (trimmer
rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a maximum of two
minutes.
LED SIGNALS
DL1
program activated (red)
DL2
gate opening M2 (green)
DL3
gate closing M2 (red)
DL4
gate opening M1 (green)
DL5
gate closing M1 (red)
DL6
automatic closing indicator (red)
DL7
photocell contact (NC) (red)
DL8
sensor contact (NC) (red)
DL9
STOP button (NC) (red)
DL10
radio code program (green)
FUSES
Fuse 1 T 8A MOTOR PROTECTION FUSE
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)
C - MOTOR ROTATIONAL DIRECTION CONTROL
1 - Set DIP 1 to ON => LED DL1 starts flashing.
2 - Press and hold the PROG button. (movement is now manually controlled - open-stop-
close-stop-open - etc.) => GREEN LEDS DL2 and DL4 are lit and the gate panels open
with a fixed lag of 2 sec. If they close instead of open, release the button and reverse the
two wires on the motor used.
3 - After opening release the PROG button and calibrate the mechanical opening stops (on
the operator).
4 - Press and hold the PROG button => RED LEDs DL3 and DL5 turn on and the gate panels
close with a time lag of 2 sec.
5 - Continue to hold the PROG button until the gate is completely closed.
6 - Leave the two doors completely closed to set the timer.
7 - Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.
N.B.: During this check the stop, the photocells and the sensors are not active.
D - SETTING THE TIMER FOR 2 MOTORS (#) WITH POWER SENSOR
ACTIVATED (DIP 7 ON)
WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY ACTIVATED.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power) => At the same time M2 is triggered to open.
5 - When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M2 (memorizing the time and the power).
6 - Press the PROG button. => M2 closes.
7 - Press the PROG button. => M1 closes and sets the lag time between M2 and M1. At
the same time LED DL1 stops flashing indicating exit from the programming procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - The gate panels will close in high-speed mode (depending on how you set the RUN
trimmer) and near total closure in the slow mode (depending on how you set the LOW-
SPEED trimmer).
9 - Upon closing the power sensors stop the gate.
10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
D - SETTING THE TIME FOR ONE MOTOR (M1) (#) WITH POWER
SENSOR ACTIVATED (DIP 7 ON)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED TO ON; DURING
PROGRAMMING THE POWER SENSOR IS CONTINUOUSLY ACTIVE.
The gate must be completely closed.
1 - Set DIP 2 to ON => LED DL1 will blink rapidly.
2 - Press the PROG button. => M1 opens.
When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops
M1 (memorizing the time and the power).
3 - Press the PROG button. => M1 closes.
At the same time LED DL1 stops flashing indicating exit from programming. Safety and
other gate commands now operate normally (inversions, stop, alarms, etc.).
Upon closing the power sensor stops the gate.
4 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE "MOTOR ROTATIONAL DIRECTION CONTROL" AND REPEAT THE DESIRED
PROGRAMMING PROCEDURE.
D - SETTING THE TIME FOR 2 MOTORS (#) WITH TIME OPERATION
(DIP 7 OFF)
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG button
=> M1 stops and M2 opens.
5 - When the mechanical opening stop is reached => wait 1 second and press the PROG
button => M2 stops.
6 - Press the PROG button => M2 closes.
7 - Press the PROG button => M1 closes setting the time lag between M2 and M1.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
8 - After the set amount of time, the gate will stop.
9 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
NOTE: The slowdown is automatically determined by the control board during the time setting
phase and is activated at about 50 to 60 cm before reaching the mechanical opening or
closing limit.
D - SETTING THE TIME FOR 1 MOTOR (#) WITH TIME OPERATION (DIP
7 OFF)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON
1 - The gate must be completely closed.
2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press the PROG
button => M1 stops.
5 - Press the PROG button => M1 closes.
At the same time LED DL1 stops flashing indicating exit from the programming
procedure.
Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).
6 - After the set amount of time, the gate will stop.
7 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
D - SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND
POWER SENSOR OPERATION
With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 flashes
slowly).
2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.
21
G
B

Publicidad

loading