Descargar Imprimir esta página

DeFelsko PosiTector GLS Manual De Instrucciones página 5

Ocultar thumbs Ver también para PosiTector GLS:

Publicidad

Idiomas disponibles

Idiomas disponibles

results are obtained by rubbing in one direction only and by
using a new portion of the wipe for each cleaning pass.
WARNING:
in this procedure. Replacement cleaning wipes are available.
Cal Standard
For some applications, it may be desirable to calibrate the
PosiTector GLS probe to a different calibration standard than the
one included with the probe. Add and manage up to 99 calibration
standards from this menu.
New
When selected, the following screen is shown.
Open
Select a calibration standard from a list of saved standards. The
calibration standard at the top of the list is the one included
within the protective base plate of the PosiTector GLS probe.
Edit
Select a calibration standard from a list of saved standards to
edit its Gloss Unit value and name.
NOTE:
The calibration standard included within the protective
base plate cannot be edited.
Do not substitute other chemicals or cleaning wipes
Adjust the Gloss Unit (GU) val-
ues using the on-screen keypad
or by pressing
Enter a name or serial number
to identify the Standard using
the on-screen QWERTY touch
keyboard.
Select OK, then follow the
prompts to take a measurement
of the desired gloss calibration
standard.
4
or
.

Publicidad

loading