Symptom
• The display shows E2 and the unit
goes off automatically, with the display
continuing to show error E2 until the
anomaly is repaired. To remove from
the display, press the On/Off key once
on the control panel or remote control.
• The display shows E3 and the unit
goes off automatically, with the display
continuing to show error E3 until the
anomaly is repaired. To remove E3
from the display, press the On/Off key
once on the control panel or remote
control.
• When the unit starts up or runs, the
unit gives out a beeping sound and
the display shows E6 (anti-freeze
sensor failure). The unit disconnects
automatically, although the display
will show error E6 until the anomaly
is repaired. To remove E6 from the
display, press the On/Off key once on
the control panel or remote control.
• Centrifugal blower or condenser
fan blocked, in short-circuit or
disconnected.
• 5A fuse of the centrifugal blower or
7.5A fuse of the condenser fan blown.
• Compressor defective or failed.
• Compressor module disconnected from
the compressor or defective.
• Poor connection in anti-freeze sensor
cables or terminals.
• Anti-freeze sensor disconnected or
faulty.