• Repair the possible obstruction of the centrifugal blower or the condenser fan; if
the error persists, replace the centrifugal blower or the condenser fan (remove the
outside cover of the unit in order to access the centrifugal blower or the condenser
fan; for the blower, also remove the evaporator access cover).
• Replace the 5A or 7.5A fuse. It is necessary to take down the control panel's front
panel to access the condenser fan or centrifugal blower fuses.
!
(If the error persists, contact the Authorised Technical Service).
• Replace the compressor.
• Connect the compressor module correctly or replace it (take down the outside cover
of the unit to access the module and the compressor).
!
(If the error persists, contact the Authorised Technical Service).
• Check and correct any possible poor contacts in anti-freeze sensor cables or
terminals.
• Connect or replace the anti-freeze sensor.
!
(If the error persists, contact the Authorised Technical Service).