Maintenance
Servicing
Please check the following before contacting the servicing department:
1. Place one cup of water (approx. 150 ml) in a glass container inside the oven and close the
door securely. The light inside should go off if the door is closed properly. Turn the oven on
for 1 minute.
2. Does the oven lamp work?
3. Does the cooling fan work? (Put your hand over the rear ventilation openings.)
4. Does the turntable rotate? (The turntable can rotate clockwise or counterclockwise. Both
directions are normal.)
5. Is the water inside the oven hot?
If the answer to any of the above questions is "NO", check the wall socket and the fuse.
If both the wall socket and the fuse are functioning properly, CONTACT AN APPROVED
SERVICING CENTER NEAREST TO YOU
Servicing Safeguards
WARNING: PROMIENIOWANIE MIKROFALOWE:
1. The high voltage capacitor remains charged after the appliance has been
disconnected; short circuit the negative terminal of HV capacitor to the oven
chassis (use a screwdriver) to discharge before touching.
2. During servicing, parts listed below may be removed and give access to potentials
above 250 V to earth.
- Magnetron
- High voltage transformer
- High voltage capacitor
- High voltage diode
- High voltage fuse
3. The following conditions may cause undue microwave exposure during servicing.
- Improper fitting of the magnetron.
- Improper matching of the door interlock, the door hinge and the door.
- Improper fitting of the switch support.
- The door, the door seal or the enclosure have been damaged.