SMOKE DUCT CLEANING (for the DEALER)
Move the lever to the right.
Open the door when the stove is off and cold.
Open the right and left ducts
Remove the front panel.
CLOSE the duct openings, replace the front
Vacuum-clean the ducts using a suitable vacuum
panel and lock the lever to the left .
cleaner, preferably our ASH VACUUM BIN.
- 34
-