You can scan the QR code to pair your smart device (app) with the controller.
System Reset:
There are three options to choose from within the System Reset menu. Device Reset allows
the user to reset ONLY the device module addressing. The Factory Reset can be used to resolve some major
problems within the controller, or if the user just wants to return the unit to factory settings. You can also
update the TCS-1 internal firmware by selecting Firmware update.
Calibration:
You can calibrate the various sensors you are using inside the grow tent by selecting the
Calibration page. There you will find options to calibrate the environmental sensors, and water monitoring
sensors.
*Note:
The MBS-PAR sensor does not require calibration.
DeadBand:
You can set your deadband setpoints that will be used with your connected device modules. The
deadband settings determine the temperature or humidity level that each module will turn on, and turn off
again.
Water Detectors:
This page will show you the status of the optional Water Detectors.Here you can select
one of two modes for the Water Detectors, Leak sensor or water confirmation sensor.
WD Delay Time:
Here you can set your Water detectors delay time.
Alarm Settings:
On the Alarm setting page, you can set your high and low limit alarm settings for your
climate, nutrients, and grow medium. When the values exceed or drop below the defined Maximum and
Minimum setpoint in the alarm settings, you will immediately be notified on the controller and through
TrolMaster's app, TM+ Pro.
EC Fan Control
The EC fan control settings determine the range of temperature and humidity that the fan
will change speed. For example, if the user Temperature setpoint is 80'F, and the Temperature Variable
Range is set to 5'F, the fan will operate at varying speeds unless the temperature was to rise above 85'F
(80+5 = 85'). If the temperature or humidity goes above this temp range setting, the exhaust fan will operate
at the maximum fan speed set by the user in the F1 settings. As the temperature or humidity drops back
towards the temperature setpoint, the fan will gradually slow down and resume to the minimum speed set
by the user in a linear fashion. The same effect happens with the Humidity Variable Range setting.
FIRMWARE UPDATES
When first installing your controller, you should verify that it has the most recent version of the operating
system / firmware. Update to the latest firmware for bug fixes and new functions that are added to the unit.
Visit our website to find out the most updated version of the firmware. You will then save and copy the
newest firmware to a MicroSD card that is 32 gb or less. To update the firmware, insert the MicroSD card in
the TCS-1 slot then go to the System Settings page and choose system reset. At the bottom you will see the
current Firmware version that is installed. To install the update, choose Firmware Update and follow the
prompts to select the file to update to.