1x MBS-TH:
1x MBS-S8:
1x MBS-PAR:
1x MBS-SD:
2x MBS-WD:
1x AMP-3:
1x PCT-1, 2 or 3:
1x PPH-1, 2 or 3:
2x WCS-1 & 3:
Once the sensors are all connected to the SENSOR port on the TCS-1, some of the sensors require you to
press the small button on the sensors to link or "address" each sensor to the TCS-1 controller. The TENT-X
controller will then automatically assign an address to the sensors sequentially. Once the sensors are
addressed, the addresses will be saved unless the user completes a factory or sensor reset within the
system setting menu.
2. Light Connections
The TCS-1 can control most brands of LED or HID lights using the two built-in lighting control channels on
the TCS-1. Each of the two channels can operate independently of each other to allow two different types or
brands of lights to be controlled. In order to control your lights, you must first plug in one of TrolMaster' s
LMA Lighting Adapters into the RJ12 ports on the bottom of the controller, labeled Line 1 and Line 2.
TrolMaster offers several types of lighting Adaptors for different brands and types of lights. If you have
questions about which adapter is correct for your lights, contact Tech Support or go to the Tent-X page on
TrolMaster' s website at www.trolmaster.com. Since each of the two lighting control channels are
independent, each control line can be set up to have its own timer settings and dimming temperature
setpoints as well as the dimming & power % that each group of lights will be operated at.
3. Device Module Connections
There are multiple device modules that can be used with the TCS-1. All of the device modules used with the
TCS-1 will be connected to the RJ12 port at the bottom of the controller, labeled DEVICES. First, connect an
RJ12 cable to the port, then connect the other end to either a Y-splitter or TrolMaster' s splitter hub
(SPH-1). If using the Y-splitter, a device module in one of the two ports and another device module to the
second port, or connect another Y-splitter to the second port to create a daisy-chain connection in order to
connect more device modules. Repeat the procedure to connect all of the device modules to the DEVICES
RJ12 port on the TCS-1 controller. When connecting multiple device modules, it can be easier to use a
single 8-port SPH-1 instead of multiple Y-splitters. Once the devices are all connected, press the small
button on the device modules to link or "address" each module to the TCS-1 controller. The TENT-X
3-in-1 temperature, humidity, and light sensor. *Comes with the TCS-1.
CO2 sensor
Full spectrum quantum sensor
Smoke detector
Water detector
Amplifier for connect the pH and EC probes
EC & temperature probe
PH probe
Water content sensor or WCS-2: Water content + EC sensor
03