4.6 Performance check
Once the product has been assembled, always check the
control handles. These should move easily and work in a
satisfactory manner.
Fig. 10 The Jøtul F 400 ECO is equipped with the
following operating options:
1
1. Handle front door. To open, lift the handle up (clockwise)
and pull out.
2. Handle
ash
door.
To
(counterclockwise) and pull out.
3. Air/ignition valve. Adjust in the horizontal direction (see fi g.
13)
4.7 Requirement for UK -
Smoke control Areas
The Clean Air Act
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the
whole or part of the district of the authority to be a smoke
control area. It is an off ence to emit smoke from a chimney of
a building, from a furnace or from any fi xed boiler if located in a
designated smoke control area. It is also an off ence to acquire
an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from
the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list
by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of
the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014.
In Northern Ireland appliances are exempted by publication
on a list by the Department of Agriculture, Environment and
Rural Aff airs under Section 16 of the Environmental Better
regulation Act (Northern Ireland) 2016.
3
2
open,
lift
the
handle
up
Página 10/65
In Wales appliances are exempted by regulations made by
Welsh Ministers.
Further information on the requirements of the Clean Air Act
can be found here: https://www.gov.uk/smoke-control-area-
rules
Your local authority is responsible for implementing the Clean
Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air
Act requirements.
The Jøtul F 400 ECO stoves have been recommended as
suitable for use in smoke control areas. Make this adjustments
to prevent complete primary air control closure.
Fig. 11
1. Open the door.
2. Pull then valve handle (A) to the right.
3. Unscrew the screws located on the inside of the front.
4. Switch the postion of the screws.
Fig. 12
5. Mount the screws.
ENGLISH
A
9