Fig. 7d indirecitly through an outside wall
Fig. 8a Mounting of external air supply connection
1. Use a cutting pliers and cut off the cover.
Fig. 8b
1. Place the external air supply connection (Ø 80) with the
hose clamp on the outside air hole.
2. Tighten with screwdriver.
8
4.4 Location of approval label
Fig. 9 Approval label
1. The approval label is located at the bottom of the stove.
4.5 Chimney and fl ue pipe
The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
For fl ue pipe dimension see "2.0 Technical Data". NB:
The chimney's diameter must be at least as big as the fl ue
pipe: Ø150 mm fl ue pipe - 177 cm
Connection to the chimney must be carried out in
accordance with the chimney supplier's installation
instructions.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
Use a fl ue pipe bend with a sweep hatch to allow sweeping.
Flue pipe bends with any change in direction infl uence/
reduce the chimney draught. This eff ect also applies
when horizontal fl ue pipes are used. Please note that it is
extremely important for connections to have a degree of
fl exibility. This is to prevent any movement in the installation
leading to the formation of cracks.
For recommended chimney draught, see «2.0 Technical
Data».
NB! The minimum recommended chimney length is 4 m from
the fl ue pipe insert. If the draught is too strong, a fl ue pipe
damper can be installed and used to reduce the draugh
If a fl ue damper is fi tted it must be of a type, which does not
block the fl ue totally. The damper should be easy to operate
and incorporate an aperture within the blade, which in a
continuous area occupies at least 20 cm
sectional area of the blade if this is greater.
The position of the damper should be recognizable from the
setting of the device.
If a draught regulator is fi tted the minimum cross sectional
area requirement shall not be applicable but the device should
be easily accessible for cleaning.