Automatic Pool Cover | Owner's Manual
®
™
on the cover, dirt or contamination in the tracks,
or something damaged on the system. Remove
any excess water or debris and try reversing the
direction. If the cover moves, then proceed with
operating the cover. If the cover will not move further
in the intended direction, call your service technician
or see Section 10: Advanced Troubleshooting
and Repair.
4.2
Auto-shutoff Operation
If your cover has been installed with a control
board with auto-shutoff, your cover will shut
off automatically when it has reached the fully
uncovered or covered position. This feature prevents
overrunning the cover in either direction to prevent
possible damage. Make sure that your cover opens
and closes evenly so that your auto-shutoff will be
able to operate properly. While operating the cover
you may stop and reverse direction at any point
between the fully opened or fully closed position.
Figure 2.
Auto-Shutoff with Amp Limiter
Once the cover has shut off automatically in one
direction you will only be able to run it in the
opposite direction. In addition, your auto-shutoff
control has an adjustable amperage stop that will
turn off the motor if the pool cover meets significant
resistance when it is operating.
If your cover stops running during operation there
is something creating resistance, such as water
on the cover, dirt or contamination in the tracks,
or something damaged on the system. Remove
any excess water or debris and try reversing the
direction. If the cover moves, then proceed with
operating the cover. If the cover will not move further
Auto-shutoff w/
Auto-shutoff w/
Amp Limiter
Amp Limiter
in the intended direction, call your service technician
or see section 10.2.
NOTE: If there has been a power interruption to your
control, the system will not operate until power
has been restored. Once power is restored, it
is possible to overrun the cover if the control is
operated in the wrong direction. Once the cover
has been run in the correct direction for just a few
feet, the shutoff sequence is restored and it will
not be possible to overrun the cover.