Levenhuk Wezzer PRO LP330 Weather Station
EN
The kit includes: display console, outdoor sensor (thermohygrometer, rain gauge, wind speed sensor, wind
direction sensor), U-bolt with mounting clamps (2 pcs.), DC power adapter (5V), user manual, and warranty
card.
Caution! Please remember that mains voltage in most European countries is 220−240V. If you want
to use your device in a country with a different mains voltage standard, remember that use of
a converter is absolutely necessary.
Getting started
Pre-installation checkout
Before installing the weather station, it is recommended that you set up the display console and multisensor
with all components ready to ensure proper operation.
Insert the batteries into the display console first and then into the multisensor.
Site survey
Perform a survey of the site before installation. Consider the following:
•
Maintenance access. Regularly clean the rain gauge and swap batteries every 2−3 years. Ensure easy
access to the weather station.
•
Radiant heat from buildings and structures. Install the multisensor at least 1.5m from any buildings,
structures, ground, or rooftops.
•
Rain and wind obstructions. For precise measurements of wind and rain, install the multisensor at
a height at least 4 times that of the nearest obstacle. For example, if the building is 6m tall, and the
mounting pole is 2m tall, the sensors should be installed at a height of at least 16m (4 х (6 − 2)).
•
Wireless range. The optimal distance between the receiver and the transmitter is up to 100m in an open
space. With obstacles in the way (buildings, trees, etc.), the maximum distance is 30m.
•
Radio interference from computers, radios, or TVs. Install the display console at least 1.5m away from
electronic devices to minimize interference.
Sensor setup
Installing U-bolts and the mounting pole
Install the included metal plates to secure the U-bolts (8) to the mounting post. The metal plate is inserted
into the groove on the bottom of the device (opposite side from the solar panel (6)). One side of the plate has
a straight edge (inserted into the groove), the other side is bent at a 90-degree angle and has a curved profile
that wraps around the mounting pole.
After inserting the metal plate, remove the nuts from the U-bolts and insert both bolts into the corresponding
holes in the plate.
Screw the nuts onto the ends of the U-bolts. Make sure to tighten them completely during final mounting.
Wind vane installation
Slide the wind vane (2) onto the shaft at the bottom of the sensor until it stops. Tighten the fastening screw
with a screwdriver (size PH0) until the wind vane is securely fastened to the axle.
8