General Notes

Fan operation
Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used
for ventilating furnace installation areas.
If the ventilation is intended to pass through smoke
or exhaust that is not in operation, the responsible area
heating inspector must give approval.
If the ventilation passes through an external wall, use a
telescope wall sleeve.

Electrical Connection

WARNING
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during installation.
Before connecting the appliance, check the household
installation. Ensure sufficient fuse protection of the house-
hold installation. Turn off power circuit at service panel and
lock out panel before wiring this appliance. Requirement:
120 VAC, 60 Hz 15 A (see rating plate).
The appliance complies with protection class 1 and must
only be operated in conjunction with a protective conduc-
tor terminal.
An all-pole isolating switch with at least a 3 mm contact
gap must be fitted in the installation. This must remain
accessible after installation.
Only a qualified electrician who takes the appropriate
regulations into account may lay or replace the
connecting cable.
Ventilation line
Note: The manufacturer is not responsible for the operation
or complaints associate with the pipe section.
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as large
a pipe diameter as possible.
The optimum extraction performance is not achieved
and fan noise is increased if exhaust air pipes are long
and rough and if there is a large number of pipe bends
or diameters less than 8" (200 mm).
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
An inner diameter of 8" (200 mm) is necessary.
Follow all standards, regulations, and laws.
Ensure that the electrical connection meets the require-
ments of the latest version of all applicable standards.
regulations, and laws in the appropriate country, especially
the following standards: National Electrical Code, ANSI/
NFPA 70*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91**.
Have a qualified electrical technician check the grounding
of the appliance.
Do not ground with a gas line.
No fuse protection in the neutral or grounding circuit.
Keep these installation instructions. Only connect the
appliance with a copper conductor. If possible, connect
the appliance to a metal cable guide directly to the fuse
box.
Ensure that the wire diameter meets the requirements of
the latest version of all applicable standards, regulations,
and laws in the appropriate country, especially the following
standards: National Electrical Code, ANSI/NFPA 70*, or
CSA Standards C22.1-94, Canadian Electrical Code, Part
1 and C22.2 No.0-M91**.
For copies of the standards listed, contact:
* National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Page 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcp30e52ucHcp34e52uc

Tabla de contenido