Problem: Yellow flame.
Possible Causes and Solutions:
1.
Check for spider webs or insect nest in the venturi and clean the venturi.
2.
New burner may have residual oil which will burn off.
3.
Clean off any food residue, grease or seasoning salts on the burner.
4.
The venturi may be misaligned and needs to be lined up over the orifice.
Problem: Flame blows out on low setting or has uneven heat distribution.
Possible Causes and Solutions:
1.
Check for spider webs or insect nests in the venturi and clean the venturi.
2.
Cold grill needs to be preheated for 5 minutes on high setting.
3.
The venturi may be misaligned and needs to be lined up over the orifices.
4.
Cold and windy weather will require you to move the grill away from the wind.
5.
Lack of fuel. Check to see that the cylinder has fuel.
Problem: Grill too hot.
Possible Causes and Solutions:
1.
Excessive flareups which require the maintenance described in the section titled "IN CASE OF GREASE FIRE".
2.
A damaged orifice or regulator which requires replacement with factory authorized parts.
3.
Buildup of grease inside the grill will require cleaning and emptying the grease tray.
4.
Choose a lower cooking temperature if using excessively high settings.
Problem: Fire at any connection.
Possible Causes and Solutions:
IMMEDIATELY shut off control knob and allow grill to cool.
1.
Gas is leaking from a faulty connection. Tighten connections with an adjustable wrench and replace damaged parts. Perform a leak
test on all connections before cooking on the grill again.
Problem: Flame behind control panel or control knob area.
Possible Causes and Solutions:
IMMEDIATELY shut off control knob and allow grill to cool.
1.
Check for spider webs or insect nest in the venturi and clean the venturi.
2.
Gas is leaking from a faulty connection. Hand tighten connections and replace damaged parts. Perform a leak test on all connections
before cooking on the grill again.
3.
The venturi may be misaligned and needs to be lined up over the orifices.
English - 13