Attention! The fitting must be installed, flushed and tested
after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Move to the left = hot water,
move to the right = cold water.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0.3 MPa:
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0.15 MPa.
To adjust the hot water limiter on single lever mixers, please
see page 36.
No adjustment is necessary when using a continuous flow
water heater.
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water.
Instantaneous water heater starts up
when cold water is selected.
10
English
Spare parts (see page 3)
1
2
3
4
5
6
7
8
9
max. 1 MPa
10
0.1 - 0.5 MPa
11
1,6 MPa
12
13
max. 80° C
14
65° C
15
approx. 32 l/min
16
17
18
19
20
21
22
23
24
25
26
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
120 chrome plated/porcelain colour
800 steel
810 satinox
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Hot water limiter incorrectly set
- Crossflow
handle Starck
handle Carlton
handle Terrano
handle Allegroh
handle Steel
handle Massaud
face plate
face plate Massaud
flange
flange Terrano
flange Massaud
nut
locking screw for handle
seal
o-ring 13x2
noise reduction
cartridge cpl.
sub plate
fixing screw
extension 25 mm
extension 22 mm
screw cover
screw cover
screw cover
screw (4)
O-ring 48x5
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange seal (13)
10492000
17092XXX
374 91 X X X
36093000
35093800
18492000
96452XXX
98678000
95010XXX
96348XXX
98684000
95007000
96059000
95008000
98128000
94073000
92730000
96447000
96454000
13595000
13596XXX
96338000
96347000
96681000
96525000
98174000